This document explains that a new parameter will be added to the SAV command and a new key added to the QsrSave API which will specify whether objects should be asynchronously brought into memory during the save processing. Async bring will only be done when saving objects from the root ('/'), QOpenSys, and user-defined file systems.

Resolving The Problem

A new parameter will be added to the SAV command and a new key added to the QsrSave API which will specify whether objects should be asynchronously brought into memory during the save processing. Asynchronous brings will only be done when saving objects from the root ('/'), QOpenSys, and user-defined file systems.

ASYNCBRING enablement was introduced as an enhancement at V6R1Mx and V7R1M0 using PTFs.
  • - SAV command Help text for ASYNCBRING



    Asynchronous bring. Specify whether objects should be asynchronously brought into memory during the save processing. Depending on the directory tree structure, the amount of memory available, and the number of objects which qualify for the save, asynchronously bringing the objects may improve save performance. The best performance improvement may be seen with a well balanced directory tree in which all objects qualify for the save. In situations where a large number of objects reside in a single directory, few objects qualify for the save, or the system is memory constrained, performance may degrade with ASYNCBRING(*YES) specified. The default is *NO. The possible values are as follows:

    o *NO Asynchronous bring is not done.
    o *YES Asynchronous brings are done



The following PTFs are required:

  • - Release V6R1M0


    MF53846
    SI46711 <- This PTF now supercedes SI44587
    SI44589
    SI44739 <- S/R PTF containing the key cover letter for the customer (PTF is approved)
    SI47800 <- This PTF now supersedes SI44739
    SI44709 <- BRMS PTF that supports ASYNCBRING
    SI47038 <- This PTF now supersedes SI44709

    Prior to ordering these PTFs, the customer should order and install the latest available superseded PTF(s):

    o SI43749
    o SI43838

    Installing the superseded PTF(s) is required to ensure the PTF can be properly removed (if needed) and to prevent the PTF from being permanently applied by the system due to requisite PTF processing.


  • - Release V6R1M1


    MF53847
    SI46711 <- This PTF now supersedes SI44587
    SI44589
    SI44739 <- S/R PTF containing the key cover letter for the customer (PTF is approved)
    SI47800 <- This PTF now supersedes SI44739
    SI44709 <- BRMS PTF that supports ASYNCBRING
    SI47038 <- This PTF now supersedes SI44709

    Prior to ordering these PTFs, the customer should order and install the latest available superseded PTF(s):

    o SI43749
    o SI43838

    Installing the superseded PTF(s) is required to ensure the PTF can be properly removed (if needed) and to prevent the PTF from being permanently applied by the system due to requisite PTF processing.


  • - Release V7R1M0



    MF53848
    SI44588
    SI45693 <- This PTF now supersedes SI44588
    SI44590
    SI44688 <- S/R PTF containing the key cover letter for the customer (PTF is approved)
    SI46812 <- This PTF now supersedes SI44688
    SI44710 <- BRMS PTF that supports ASYNCBRING
    SI45327 <- This PTF now supersedes SI44710

    Prior to ordering these PTFs, the customer should order and install the latest available superseded PTF(s):
    o SI43750
    o SI44528

    Installing the superseded PTF(s) is required to ensure the PTF can be properly removed (if needed) and to prevent the PTF from being permanently applied by the system due to requisite PTF processing.

    Note: There are additional steps required to enable the ASYNCBRING enhancement for BRMS save operations. This is documented in the BRMS PTF cover letter, Item 13:


  • - Cover Letter Instructions - BRMS Support for ASYNCBRING



    In V6R1 and above, override support for the new ASYNCBRING key on the QsrSave API to help improve IFS save performance is now possible using one of the following commands:
    (Important Note: Enter the commands in uppercase only.)

    To enable the new ASYNCBRING key:
    CALL PGM(QBRM/Q1AOLD) PARM('PARMOVR' '*ADD' 'ASYNCBRING' '*YES')

    To disable the new ASYNCBRING key:
    CALL PGM(QBRM/Q1AOLD) PARM('PARMOVR' '*ADD' 'ASYNCBRING' '*NO ')

    To remove the override, use the following command (default is *NO):
    CALL PGM(QBRM/Q1AOLD) PARM('PARMOVR' '*REMOVE ' 'ASYNCBRING')

    To show the current override being used, use the following command:
    CALL PGM(QBRM/Q1AOLD) PARM('PARMOVR' '*DISPLAY' 'ASYNCBRING')



At V7R2M0 and above, there is a control group attribute that regulates this parameter.  Information on this parameter in BRMS can be found here:
BRMS Wiki

To have ASYNCBRING active for the GO SAVE 21 option you will need to change the default setting for that parameter from *NO to *YES

[{"Type":"MASTER","Line of Business":{"code":"LOB68","label":"Power HW"},"Business Unit":{"code":"BU070","label":"IBM Infrastructure"},"Product":{"code":"SWG60","label":"IBM i"},"ARM Category":[{"code":"a8m0z000000cwp6AAA","label":"Save Restore"}],"ARM Case Number":"","Platform":[{"code":"PF012","label":"IBM i"}],"Version":"6.1.0;7.1.0;and future releases"}]