IBM Support

PH69960: When a CICS/TS 6.1 region uses a CICS/TS 6.2 version of DFHDTSVC, Data Table accesses work but uses more CPU than normal.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible.

Error description

  • At CICS/TS 6.1 and below, DFHDTSVC is downward compatible, and
    it is shipped in SDFHLINK. At CICS/TS 6.1 and below, when there
    are multiple releases of CICS in the same LPAR, it makes sense
    to put the highest release of SDFHLINK in LNKLST or LPA.  All
    releases of CICS could then use highest version of DFHDTSVC.
    Starting with CICS/TS 6.2, that is no longer the case.
    
    CICS/TS 6.2 makes a change to DFHDTSVC that makes it no longer
    downward compatible with prior releases.  As such, CICS/TS 6.2
    ships DFHDTSVC in SDFHAUTH.   Prior releases of CICS should not
    use the CICS/TS 6.2 version of DFHDTSVC.
    
    If a CICS/TS 6.1 (or lower) CICS region loads and uses a CICS/TS
    6.2 (or higher) version of DFHDTSVC, Data Tables accesses still
    work, but they do not work efficiently.   Read requests do not
    access the loaded data table directly.   All requests, including
    Reads, are function shipped to the owning FOR.  This causes lots
    more CSMI tasks in the FOR, and more overall CPU used.  There is
    no message warning that a CICS/TS 6.1 (or lower) CICS region is
    incorrectly using a CICS/TS 6.2 (or higher) version of DFHDTSVC.
    
    
    There needs to be a message warning of this mistake.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS Users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: When planning to upgrade to CICS TS 6.2 *
    *                      or higher, remote file control requests *
    *                      against Data Table files will be        *
    *                      function shipped if the wrong version   *
    *                      of DFHDTSVC is used.                    *
    ****************************************************************
    Prior to CICS TS 6.2, DFHDTSVC was backwards compatible for
    upgrade purposes and was sorted in the LPA. Due to the changes
    made in CICS TS 6.2, DFHDTSVC was moved to the SDFHAUTH library
    so it would not be used be used by lower level versions of CICS
    when upgrade planning.
    
    If the CICS TS 6.2 SDFHAUTH library is placed in the DFHRPL
    concatenation before the lower level CICS's SDFHLINK library,
    then the lower level CICS release will use the CICS TS 6.2
    version of DFHDTSVC.
    
    The consequence of this is that all remote data table file
    control requests will be function shipped to the FOR rather
    than taking advantage of Data Table Services.
    

Problem conclusion

Temporary fix

Comments

  • DFHFCDTS has been altered to issue new error message
    DFHFC0432 to state that the wrong version of DFHDTSVC is being
    used by CICS TS and that all remote data table file control
    requests will be function shipped.
    
    New Message DFHFC0432 has been added to the CICS TS for z/OS 6.1
    Documentation site.
    
    DFHFC04032 E applid Shared access to remote data tables cannot
    be provided by this CICS system because the version of DFHDTSVC
    being used is incompatible with this release.
    
    Explanation
    CICS is about to issue a file control request against a remote
    data table but cannot do so because the version of DFHDTSVC
    being used is incompatible with this release.  This will prevent
    this CICS system being able to access the data table using
    cross memory services, so the file control request will be
    function shipped.
    
    System Action
    Processing continues with remote data table file control
    requests being function shipped. This will result in a
    performance degradation.
    
    Message DFHFC0432 will be reissued if any subsequent request is
    made to read or browse a remote data table. However, message
    DFHFC0432 is not issued more often than once an hour.
    
    User Response
    The CICS system should be pointed at the correct version of
    DFHDTSVC. DFHDTSVC supplied with CICS TS V6.2 is not backwards
    compatible.
    
    Module
    DFHFCDTS
    
    XMEOUT parameters/Message inserts
    1. applid
    
    Destination
    Console
    
    Applicable releases
    5.6 , 6.1
    

APAR Information

  • APAR number

    PH69960

  • Reported component name

    CICS TS Z/OS V6

  • Reported component ID

    5655YA100

  • Reported release

    400

  • Status

    CLOSED UR3

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2026-02-03

  • Closed date

    2026-07-31

  • Last modified date

    2026-08-06

  • APAR is sysrouted FROM one or more of the following:

    PH67553

  • APAR is sysrouted TO one or more of the following:

    UO08831

Modules/Macros

  • DFHAMFC  DFHAMPFI DFHAPSM  DFHAPTR5 DFHBRNS  DFHDMPCA DFHDMRM
    DFHDT64M DFHDTLA  DFHDTLX  DFHEDFX  DFHEIFC  DFHEIQCF DFHEIQDN
    DFHEIQDS DFHEIQMS DFHEIQSA DFHEIUOW DFHESE   DFHFCAT  DFHFCBD
    DFHFCBU  DFHFCCA  DFHFCDL  DFHFCDN  DFHFCDO  DFHFCDR  DFHFCDTS
    DFHFCDTX DFHFCDU  DFHFCDUF DFHFCDW  DFHFCDY  DFHFCES  DFHFCFL
    DFHFCFR  DFHFCFS  DFHFCIN1 DFHFCIN2 DFHFCIR  DFHFCL   DFHFCLF
    DFHFCLJ  DFHFCLJ1 DFHFCM   DFHFCMT  DFHFCN   DFHFCNQ  DFHFCOR
    DFHFCQI  DFHFCQR  DFHFCQS  DFHFCQT  DFHFCQU  DFHFCQX  DFHFCRC
    DFHFCRC2 DFHFCRD  DFHFCRF  DFHFCRL  DFHFCRN  DFHFCRO  DFHFCRP
    DFHFCRR  DFHFCRS  DFHFCRV  DFHFCSD  DFHFCSDS DFHFCST  DFHFCU
    DFHFCVC  DFHFCVR  DFHFCVS  DFHFCXDF DFHFRDUF DFHISFS  DFHMEFAC
    DFHMEFAE DFHMEFAK DFHMIRS  DFHSTFC  DFHSTLS  DFHSTP   DFHW2FI
    DFHW2FR  DFHXFP   DFHXFQ   DFHXFRM  DFHXFX
    

Fix information

  • Fixed component name

    CICS TS Z/OS V6

  • Fixed component ID

    5655YA100

Applicable component levels

  • R400 PSY UO08831

       UP26/08/06 I 1000

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1","Line of Business":{"code":"LOB70","label":"Z TPS"}}]

Document Information

Modified date:
06 August 2026