A fix is available
APAR status
Closed as program error.
Error description
If two tasks issue an EXEC CICS PERFORM SHUTDOWN command around the same time, there is a timing window where they both may attempt to read and parse the shutdown PLT programs. When this occurs, the storage which should end up holding the names of the shutdown PLT programs becomes corrupted and points to garbage. . CICS does not realize this and tries to link to programs with garbage names until it comes across some values which end the loop. . This may result in many DFHTM1752 messages, DFHME0121 messages, and perhaps 0C4 and similar abends. 01.00.59 STC12345 +DFHTM1752 CICSABCD PLT - program not available. 01.00.59 STC12345 +DFHME0121 CICSABCD 400 400 The first attempt at formatting message DFHTM1718, TD queue CSSL, has 400 failed - Invalid DBCS format Additional Keyword(s): Termination, TM1752, ME0121 KIXREVACC
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS users. * **************************************************************** * PROBLEM DESCRIPTION: DFHTM1752 PLT - program not available * * issued during CICS Shutdown if two * * tasks issue SHUTDOWN at the same time. * **************************************************************** Two CICS tasks each issue PERFORM SHUTDOWN at the same time. The second SHUTDOWN task does not detect that shutdown is in progress and causes storage corruption which results in many DFHTM1752 PLT - program not available messages being produced. Additional keywords: MSGDFHTM1752 PROGBUFF
Problem conclusion
CICS has been corrected to prevent storage corruption in the situation where two tasks issue PERFORM SHUTDOWN at the same time.
Temporary fix
Comments
APAR Information
APAR number
PH68808
Reported component name
CICS TS Z/OS V6
Reported component ID
5655YA100
Reported release
500
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-11-03
Closed date
2026-02-25
Last modified date
2026-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UO06935 UO06936
Modules/Macros
DFHAPTB
Fix information
Fixed component name
CICS TS Z/OS V6
Fixed component ID
5655YA100
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.