Error description

  • New Instructions:
    For the latest up to date instructions on how to request a
    SYSMDUMP when running under Language Environment see article:
    https://www.ibm.com/support/pages/node/7267899
    
    
    Old instructions:
    Here are directions on how to request a SYSMdump in the various
    environments:
    *****
    Batch (IMS, Webserver, etc.):
    *****       1. Specify the following Runtime options:
             ABTERMENC(ABEND)  TERMTHDACT(UADUMP) TRAP(ON,SPIE)
             For information about how to specify Runtime options
             please refer to the section "Specifying run-time
             options under z/OS batch" in the " XL C/C++ User's
             Guide.
          2. Include a SYSMDUMP DD card in the JCL specifying
             SPACE=(CYL,(100,100),RLSE),DISP=(NEW,CATLG,DELETE),
             DSN=dump_dataset_name,LRECL=4160,RECFM=FBS
                (Info apar II11016 explains how to find the
                 PSW and Registers at the time of failure.)
       Note: Ensure that your IEADMR00 Parmlib member reflects
             the following SDATA defaults:
         SDATA=(CSA,LPA,LSQA,RGN,SQA,SUM,SWA,TRT,ALLNUC,GRSQ)
    ****
    CICS:
    ****          A transaction dump should be produced for all LE
             ABENDU40xx series abends, except ABENDU4038.
             If a transaction dump is not enough, request a
             CICS system dump:
             1. Use the CICS supplied CEMT transaction:
                CEMT SET TRD(40xx) SYS ADD
                This will produce a CICS system dump.
                (Refer to the CICS-Supplied Transactions Manual)
       Note: A CICS system dump of an ABENDU4038 is not
             helpful because it is taken at the time of
             of the last termination, not at the point of
             detection. Instead, specify the following:
             TERMTHDACT(UADUMP) ABTERMENC(ABEND) TRAP(ON,SPIE)
             This will produce a CICS transaction dump with
             for an ABENDU4039
             (Ref. OS/390 Language Environment for OS/390
              Customization)
       Note: SLIP commands on C=U40xx will not work
             in CICS. SLIP commands on C=0Cx will
             work in a CICS environment but not in batch.
             TERMTHDACT(UADUMP) ABTERMENC(ABEND) TRAP(ON)
             produces a CICS transaction dump. It will
             never produce a SYSUDUMP/SYSABEND/SYSMDUMP
             since LE's ESTAE routine does not get
             driven.
             (Info apar II13228 explains how to find the
              PSW and Registers at the time of failure.)
    -  Additional procedure to get a SVCdump for 40xx abends
      under CICS:
     Here are the steps to get a SDUMP for a specific
     40xx transaction ABEND under CICS:
       1) Make sure the CICS region is started with the
          DUMP=YES sysin input (SIP) parameter.
       2) Make sure the SYS1.DUMP- datasets are available.
          Most customers should have all this already setup.
          As an alternative, dynamic allocation facility may be
          used as shown in example below.
          -
              DUMPDS ALLOC ADD,VOL=xxxxxx
              DUMPDS ALLOC=ACTIVE
          After these commands, MVS will dynamically
          allocate datasets on the xxxxxx volume containing
          the dump with the following type of name:
                   SYS1.DUMP.D970910.T191701.SY1.S00001
       3) Once the CICS region is up, signon and issue the
          following:
              'CEMT SET TRD(40xx) ADD SYS'
          Substituting the real dump code eg: 4088 for 40xx
          Below is a sample of what CICS sends back for this:
          SET TRD(4088) ADD SYS
           STATUS:  RESULTS - OVERTYPE TO MODIFY
            Trd(4088) Tra Sys     Loc Max( 999 ) Cur(0000)
       4) Now run the transaction that creates the U40xx ABEND.
          A system, or SVC dump, should be produced at the point
          of the abend. This procedure will work for any
          transaction dump under CICS, not just U40xx ABENDs.
    ********************
    UNIX System Services (OE / Shell environment):
    ********************  Prior to OS/390 2.7, go to the following
    URL:
           http://www.s390.ibm.com/le/assist/support/ii10573.html
     At OS/390 2.7 or later:
     1. Specify where to write the system dump:
       To write the system dump to a dataset, issue the command:
           export _BPXK_MDUMP=filename
       where filename is a fully qualified dataset name with
           LRECL=4160 and RECFM=FBS
     2. Specify Language Environment run-time options:
           export _CEE_RUNOPTS="TERMTHDACT(suboption)"
       where suboption is UADUMP (preferred), UAONLY, UATRACE,
       UAIMM.  If UAIMM is set, TRAP(ON,NOSPIE) must also be
       set. Once documentation has been gathered, please revert
       back to TRAP(ON,SPIE) and the previous TERMTHDACT setting.
     3. Rerun the program and the dump will be written to
       the specified dataset.
    ***
    DB2:
    ***
    To override LE Run-Time Options under DB2, see II13232.
    

Local fix

Problem summary

Problem conclusion

Temporary fix

Comments

  • Closing for publication
    

APAR Information

  • APAR number

    II10573

  • Reported component name

    PA LIB INFO ITE

  • Reported component ID

    INFOPALIB

  • Reported release

    001

  • Status

    CLOSED CAN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    1997-06-11

  • Closed date

    2020-03-20

  • Last modified date

    2026-04-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSSN3L","label":"z\/OS Communications Server"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"001","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
27 April 2026