# tail -10f /var/adm/sw/swagent.log
* Summary of Analysis Phase:
ERROR: Exclude SFM-CORE.SFMUI-PROPPAGE,r=C.07.17.03
ERROR: Exclude SFM-CORE.SFMUI-PROPPAGE-IA,r=C.07.17.03
ERROR: 2 of 113 filesets had Errors.
* 17 of 113 filesets will be Skipped.
* 94 of 113 filesets had no Errors or Warnings.
ERROR: The Analysis Phase had errors. See the above output for
details.
解决过程:
1. 卸载WBEM相关包(可以不用卸载)
[PROD root@xxx:/#] swlist |grep -i wbem
ProviderDefault B.11.31.1403 Select WBEM Providers
WBEMMgmtBundle C.17.01 WBEMMgmtBundle
[PROD root@xxxx:/#] swlist -l product|grep -i wbem
CLUP C.16.01 WBEMMgmtBundle
SCSI-Provider B.11.31.1403 CIM/WBEM Provider for SCSI HBA
WBEMP-FCP B.11.31.1705.02.01 FC Provider - CIM/WBEM Provider for Fibre Channel HBAs
WBEMP-FS B.11.31.1009 HP-UX File System CIM Provider.
WBEMP-IOTreeIP B.11.31.1403 CIM/WBEM Indication and Consolidated Status Provider for IOTree subsystem
WBEMP-LAN B.11.31.1707.01.01 LAN Providers - CIM/WBEM Providers for Ethernet interfaces.
WBEMP-Storage B.11.31.1705.02.01 Storage Provider - CIM/WBEM Provider for Storage
WBEMServices A.02.13.06.04 WBEM Services CORE Product
vmProvider B.06.30 WBEM Provider for Integrity VM vmProvider
# swremove -x enforce_dependencies=false WBEMMgmtBundle
Remove the WBEM directories:
# cd /var/opt
# rm -r wbem
# cd /opt
# rm -r wbem
NOTE: Kill any processes that might stop you from removing theses directories.
The fuser -u command will help find any running processes (icapd will probably need to be killed).
2. 需重新安装SFM(SysFaultMgmt)
目前HP-UX 11.31 已经没有单独的SysFaultMgmt包,通过HP-UX 11.31系统光盘进行安装。
(1) 设备的光驱可用
[PROD root@xxxx:/#] ioscan -fnC disk
Class I H/W Path Driver S/W State H/W Type Description
========================================================================
disk 0 0/0/0/1/0/0/0.0.0 sdisk CLAIMED DEVICE HP LOGICAL VOLUME
/dev/dsk/c0t0d0 /dev/dsk/c0t0d0s2 /dev/rdsk/c0t0d0 /dev/rdsk/c0t0d0s2
/dev/dsk/c0t0d0s1 /dev/dsk/c0t0d0s3 /dev/rdsk/c0t0d0s1 /dev/rdsk/c0t0d0s3
disk 1 0/0/0/1/0/0/0.0.1 sdisk CLAIMED DEVICE HP LOGICAL VOLUME
/dev/dsk/c0t0d1 /dev/rdsk/c0t0d1
disk 8 0/0/0/31/2.0.0 sdisk CLAIMED DEVICE hp DVDRAM GTA0N
/dev/dsk/c1t0d0 /dev/rdsk/c1t0d0
[PROD root@xxx:/#] mount /dev/dsk/c1t0d0 /mnt
[PROD root@xxx:/#] swinstall -s ./mnt
只需选择SysFaultMgmt 重新安装即可。
(2)设备的光驱不可用,需要把SysFaultMgmt包从系统光盘中导出来。
# mkdir /mydepot
# swcopy -x enforce_dependencies=true -s /mnt SysFaultMgmt @ /mydepot ? 需要dependency 的包,就改成true
# tar -zvf mydepot.tar /mydepot
导出来之后也可以生产成depot文件
swpackage -x target_type=tape -s /mydepot -d /tmp/mydepot.depot
安装完成之后需验证:
#swverify <WBEMMgmtBundle>
#swverify <SFM-CORE>
#grep -i error /var/adm/sw/swagent.log
来自 “ ITPUB博客 ” ,链接:http://blog.itpub.net/31401608/viewspace-2148147/,如需转载,请注明出处,否则将追究法律责任。
转载于:http://blog.itpub.net/31401608/viewspace-2148147/
本文介绍了解决HP-UX系统中SysFaultMgmt (SFM) 安装错误的方法,包括卸载和清理WBEM相关组件,以及重新安装SFM的过程。对于光驱可用或不可用的情况提供了不同的解决方案。